Pep Nation Lab
Analytical Services
Certificate Of Analysis
Report No. BACW-2608-1003
ProductBAC Water (Bacteriostatic Water)
Lot NumberPNL-BACW-2608-1003
CAS8013-75-0
Test DateAugust 8, 2026
AppearanceClear Colorless Solution
StorageStore At 36 To 46 F
Analytical Results
| Test | Method | Result | Specification |
|---|---|---|---|
| Purity | RP-HPLC | 99.47% | Not Less Than 98.0% |
| Identity (Mass) | ESI-MS | Not Reported | Report |
| Net Peptide Content | Nitrogen Analysis | 88.8% | Report |
| Water Content | Karl Fischer Titration | 3.54% | Not More Than 8.0% |
HPLC Chromatogram
Method: C18, 4.6 X 250 Mm, 5 Um, 214 Nm, 214 nm
Testing Laboratory
WuXi AppTec Lab Testing Division
Third Party: Yes
Accreditation: ISO/IEC 17025, GMP
Reviewed And Approved By
Dr. Wei Chen
Dr. Wei Chen
Senior Bioanalytical Scientist
Approved August 8, 2026
Scan To Verify This Lot